Precision-turbo-and-engine BigStuff3 GEN3 PRO SEFI System Hardware & BigC Manuel d'utilisateur Page 96

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 138
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 95
BigStuff3 Pro SEFI System
Version 2.1 – February 2011 89
58. Individual Cylinder - Spark
The fixed inputs in the table below represent the firing order configured during the firing order
configuration process (Firing_Order_Config
). The input cells allow the user to define the amount of
timing retard (up to 10
o
) for or each cylinder in the table. Timing corrections are made to the values in
the Spark Table.
Note: The GEN3 LS1 Coil-on-Plug (COP) and the “Stand-alone COP” systems are the only GEN3
systems with bi-directional timing compensation.
59. Individual Cylinder - Fuel
The fixed inputs in the table below represent the firing order configured during the firing order
configuration process (Firing_Order_Config
). The input cells allow the user to define the percent of
fuel to be increased or decreased (up to 25%) for or each cylinder in the table. The individual fuel
correction values modify the base pulse width in the Fuel Table.
To change a value in these tables, move the cursor using the PC’s mouse or arrow keys to the cell to be
changed. Input the desired value and hit
“Enter” to save the change.
Vue de la page 95
1 2 ... 91 92 93 94 95 96 97 98 99 100 101 ... 137 138

Commentaires sur ces manuels

Pas de commentaire