BigStuff3 Pro SEFI System
Version 2.1 – February 2011 108
77. Configure Replay
To configure Replay, open the Configure Replay drop down screen as shown above. The following
screen will open.
Signals Displayed
– Select the signals you would like logged and displayed by checking the box next
to the desired signal. Check the “ALL OFF” or “ALL ON” toggles the bottom of the table to turn all
the signals off or on respectively. Any signal checked will be logged and displayed.
Replay Duration
– The length of time the GEN3 ECU will log data, once initiated by the TPS Trigger
Level setting. The data logging duration can be set from one (1) to eighteen (18) seconds.
TPS Trigger Level
– The throttle position (TPS position in degrees) that will trigger the GEN3 ECU to
begin logging data internally.
Sample Rate
– If the GEN3 system is equipped with the “Extended Replay” option, up to 4 different
sample rates/recording times can be selected as follows: