Precision-turbo-and-engine BigStuff3 GEN3 PRO SEFI System Hardware & BigC Manuel d'utilisateur Page 27

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 138
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 26
Switched 12V from the vehicle
Brake Switch -12V
applied to this wire
when the brake pedal
is depressed
BigStuff3 Base System - Data Log Trigger/Timer Enable - Wiring Diagram
Using the Brake Pedal Switch
A C DB
“Boost Connector” from
Main Wire Harness
Relay
86
30
85
87
87a
Timer Enable Wire
Ground
Required ON/
OFF Switch to
turn the “Replay
Trigger” signal
On and Off.
With all GEN3 base systems, the Boost connector location “A” is used to enable two (2) functions.
1. The internal timer, referred to as the “Timer Enable”. No matter how the GEN3 system is configured,
or what options the system has, Pin A of the Boost connector will always
act as the internal timer trigger
wire (used for boost and traction control, and other optional features). The timer enable wire (connector
location “A”) must have 12V applied to it at the exact moment the system is configured to start a
timing sequence, like boost or traction control. Initiating both the timing sequence (Timer Enable) and
internal data logger (DAI trigger) can be accomplished by inverting the 12V signal from the brake switch
or trans-brake as shown in the diagram above.
2. Internal data logger (know as the Replay function) trigger wire.
Vue de la page 26
1 2 ... 22 23 24 25 26 27 28 29 30 31 32 ... 137 138

Commentaires sur ces manuels

Pas de commentaire