Precision-turbo-and-engine BigStuff3 GEN3 PRO SEFI (LS1) System Hardware & Manuel d'utilisateur Page 95

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 122
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 94
BigStuff3 Pro SEFI System (LS1)
Version 1.0 94
Enable/Disable Learning - To enable or disable Learning, left mouse click the appropriate
button.
Learning Parameters Assuming “Learning Enabled” was selected, the following parameters
need to be set.
Positive & Negative Limit The correction limit (+/-25%) that the ECU will allow the
Learning function to modify the base fuel table values.
Delay – The amount of time the engine needs to be operating within a given speed and
load cell before the ECU will allow the Learning function to become active.
To change a value in these tables, move the cursor using the PC’s mouse or arrow keys to the
cell to be changed and input the desired value. Then click on OK to save the changes.
67. Learning Display Table
The three (3) cell by four (4) cell Learning Display Table corresponds to the sixteen (16) cell
by sixteen (16) cell base fuel table. One cell in the Learning Display Table covers sixteen (16)
cells in the base fuel map. As is the case with the base fuel map, the X-axis represents engine
RPM and the Y-axis represents engine Load.
Vue de la page 94
1 2 ... 90 91 92 93 94 95 96 97 98 99 100 ... 121 122

Commentaires sur ces manuels

Pas de commentaire